Electronic timer/counter STS 405

Timer and counter STS-405 is a microprocessor device that can operate as a 4-digit programmable counter with multiple input and output modes or a 4-digit timer with multiple time ranges and output modes as well as an 8-digit counter totalizer which counts incoming input pulses. The device has an input press (multiplier / divisor) for a counter function, input filters for both functions, and bank with set limit values, selecting which ones are active. Upon reaching the limit value, one of the two outputs, which may be relay or optocoupler, respectively responds.

Technical parameters and connection schemes

Purpose

Timer and counter STS-405 is a microprocessor device that can operate as a 4-digit programmable counter with multiple input and output modes or a 4-digit timer with multiple time ranges and output modes as well as an 8-digit counter totalizer which counts incoming input pulses. The device has an input press (multiplier / divisor) for a counter function, input filters for both functions, and bank with set limit values, selecting which ones are active. Upon reaching the limit value, one of the two outputs, which may be relay or optocoupler, respectively responds.

TECHNICAL PARAMETERS:

Power supply:
– supply voltage – 90 – 230Vac or 24Vac / dc – on request;
– power consumption – <2VA.
Indication:
– Display of seven segment indicators:
PV: 4 red digits 9mm;
SV: 4 red figures 7mm;
– indication of outputs and modes:
– 4 red LEDs (C, O1, O2, T);
– 3 green LEDs (H, M, S);
Non-volatile memory:
– EEPROM
Counter:
– Maximum counting speed: 5kHz.
– range of the current counter: -999 to 9999.
– Input modes: up rising edge, upward falling edge, down rising edge, down
falling edge, up / down 1, 2, 3.
– Output modes: Counter mode 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12.
Timer:
– time intervals: 0.000 – 9.999s, 0.00 – 99.99s, 0.0 – 999.9s, 0 – 9999s,
0 min 00 s – 99 min 59 s, 0.0 – 999.9 min, 0 h 00 min – 99 h 59 min, 0.0 – 999.9 h,
0 – 9999h.
– timer mode: up, down.
– Output modes: Timer mode 1, 2, 3, 4, 5, 6.
Inputs:
– three digital NPN or PNP (up to 5kHz), selected in the menu.
– for counter: 1 – INP1, 2 – INP2, 3 – Reset.
– for timer: 1 – Start, 2 – Gate, 3 – Reset.
– input signal duration INP1: 0.1 – 999.9 ms, set.
– Duration of input signal Start: 1ms or 20ms, selected.

Outputs:
– 24V dc – max. output current – 250mA;
– two relay – NO + NC 5A / 250VAC or optocoupler – 0.1A / 30V.
Interface:
RS485 – two-wire
Connection: Screw terminals – dismountable.
Dimensions: 36x72x80 (95).
Material: plastic.
Operating temperature range: 0 .. + 50 ° C.
Operating humidity: 0 .. 80% RH
Degree of protection:
– on the panel – IP 04;
– on the terminals – IP 02.
Storage conditions:
– temperature – -10 .. +60 С

Legend name

Таймер / брояч STS - 405

CONNECTION SCHEME

Таймер / брояч STS - 405

DIMENSIONS

Таймер / брояч STS - 405

MODES

Таймер / брояч STS - 405
Mode key: When you press this button for more than 3 seconds, enter the menu: „Initial setting level.” Short press to go to the next parameter in the current menu, remembering the previous one.
Shift key: When you press this button for more than 3 seconds, enter the menu: „Adjustment level.” When you briefly press the next digit (right to left), change the value of a parameter in the current menu or consecutively change (alternate) the parameter values.
Up key: Pressing this button for more than 3 seconds will enter the menu: „Function setting level.” When pressed briefly, it increases with one current value of the digit (0 – 9) that is currently changing.
Clear key: If you press this button for more than 3 seconds, enter the menu „Communications setting level.” By briefly pressing this button in programming mode, the current value of the parameter currently being changed is reset. pressing in the operating mode resets the display to „Present value display” and in „Total count” and „Set value display”
Menu: Initial setting level

Таймер / брояч STS - 405

Таймер / брояч STS - 405

Меню: Adjustment level

Таймер / брояч STS - 405

Output modes for the timer function

Таймер / брояч STS - 405
Output pulse for modes 1 and 2:
Exit pulse duration when the set value is 0s.

.Таймер / брояч STS - 405

Output pulse duration when the set value is greater than 0s.

The time that the ON time is on must be less than the set value.

Input modes for counter function

Таймер / брояч STS - 405

Output modes for counter function

Таймер / брояч STS - 405

Output modes for counter function

Таймер / брояч STS - 405
Example: Using STS – 405 as a counter.
– Input mode: UP (Increment) mode.
– Output mode: Count mode 1.
– Output time relay1 (output impulse relay 1): 3.00s.
– Output time relay2: 3,00 s.
– Input filter: Signal width count input: 0.1ms.
– Decimal point position: 0000.
– Prescale value: 1,000.
Таймер / брояч STS - 405

Example: Using STS – 405 as a timer.

– Time range: 0.00 – 99.99 s.
– Timer mode: Up (Up).
– Output mode: Timer mode 1.
– Output time relay1 (output impulse relay 1): 3.00s.
– Input filter signal width Start input: 20 ms.

Таймер / брояч STS - 405
When one of the buttons is held uninterrupted for more than three seconds, it switches from operating mode to the parameter change mode in the current menu. After PASS —- appears in the display, mode changes to entering the access password, and Clear returns to the operating mode without resetting the current display. Use the buttons to enter the password, from left to right. With the Up button increases with one digit that is currently changing. With the Shift button, you move to the next digit to the left. The Clear button resets the entered password and re-enters the password. After entering the four digits of the password, it is confirmed with the Mode button and if it is correct enter the menus. Access password 1234. Depending on which key is going out of the operating mode and entering the password, it goes to the menus as follows:
– MODE: Initial setting level,
– SHIFT: Adjustment level,
– UP: Function setting level,
– CLEAR: Communications setting level.
If the password is incorrect, the display shows PASS ERR. If the Mode button is pressed, password is re-entered, and when Clear is pressed, it returns to working mode.
Menu – Initial setting level:
– Select function – timer or counter.
– Selection of input mode with counter function – see input mode diagrams for counter function.
– Select the timer timer range – see the ranges described in the Initial setting level menu.
– Timer mode for timer function – Increase / decrease mode.
– Selection of output mode for counter function – see output mode diagrams for counter function.
– Selection of output mode with timer function – See the output mode diagrams for the timer function.
– Output pulse duration for output 1 for tuneter function (operating modes 1 and 2) and counter function – set from 0.00 to 99.99 seconds. At 0.00, the output only changes its status.
– Output pulse duration for output 2 for counter function – set from 0.00 to 99.99 seconds. At 0.00, the output only changes its status.
– Input filter, count input input input time rising edge, upward edge, down rising edge, set from 0.001 to 999.9 milliseconds.
– Input filter, start input signal Start with timer function – choose between 1 and 20 milliseconds.
– Position of the decimal point of the display with the current value in the counter function – choose between 0 / 0,0 / 0,00 / 0,000.
– Input press (0.001 to 9.999) for counter function. Menu – Adjustment level:
– Set value 1 in bank 1 (limit 1, bank 1) for counter function.
– Set value 2 in bank 1 (limit 2, bank 1) for counter function.
Set boundary value 2 must be greater than boundary value1
– Four banks with two borders when the use of SV bank is chosen.
– Choosing a bank, which limits are active in working mode.
– Setpoint, bank 1 (limit) for the timer function.
– Four banks with boundary values ​​when using SV bank.
– Choose a bank, which limit is active in working mode.
– Time during which the output is switched on when operating mode 6 for the timer.Menu – Function setting level:
– Input type – Choose between PNP / NPN.
– Using SV bank, on / off. of a bank with established limit values.
– On / Off of a counter-totalizer for a counter function.
– Time to automatically return to working mode if the buttons are not pressed – set from 0 to 99 seconds. This function is off in 0 seconds. – Communications setting level:
– On / Off of communication mode.
– Device communication number.
– Speed ​​speed.