level sensor PTD102
Hydrostatic level sensor with current output PTD102
March 12, 2019
System for level control STS303
System for level control STS303
March 12, 2019

Hydrostatic level sensor with current output PD102

The sensor is designed to measure the fluid level by reading the hydrostatic pressure. The electrical connection is two-wire and the sensor is powered by the line. Back-up protection is provided. The sensor is mounted on a DIN rail above the level of the vessel. It is enclosed by a pneumatic valve 6×4.

Technical parameters and connection schemes

TECHNICAL PARAMETERS:

The sensor is designed to measure the fluid level by reading the hydrostatic pressure. The electrical connection is two-wire and the sensor is powered by the line. Back-up protection is provided. The sensor is mounted on a DIN rail above the level of the vessel. It is enclosed by a pneumatic valve 6×4.
Supply voltage: 24Vdc / 18-30Vdc /.
Inlet pressure: 0-100 mbar.
Maximum permissible overload: 750 mbar.
Fluid isolation: air.
Initial setting time: <1 sec.
Output: 4 – 20mA.
Linearity: <1%.
Output load resistance: <500 Ohm.
Electrical connection: cable 2×0,34 + screen.
Mechanical connection: – pneumatic brake 6×4.
– DIN rail.
Dimensions: as per app.
Housing material: plastic.
Operating temperature: 0 .. + 60 ° C.
Degree of protection: Ip40.

DIMENSIONS:

 

CONNECTION SCHEME

RECOMMENDED INSTALLATION