block drivers 4 chanel STS322
Block drivers 4 channels STS 322
Μάρτιος 12, 2019
MD04 magnetic sensor
Magnetic hall sensor MD04 for pneumatic cylinder
Μάρτιος 14, 2019

Inductive sensor M40 – IS40

To monitor the minimum speeds for conveyor belts, augers, shafts and other rotating parts. After the power supply, the sensor output is held on for about 10 seconds, sufficient for slow-moving slow motion mechanisms. With a number of pulse pulses greater than the set, the output remains on. With a number of pulse pulses less than the set, the output is turned off.

Technical parameters and connection schemes

To monitor the minimum speeds for conveyor belts, augers, shafts and other rotating parts. After the power is turned on, the sensor output is turned on
for a time of 10 seconds, sufficient for slow-moving slow motion mechanisms. With a number of pulse pulses greater than the set, the output remains on. When the number of pulses for a revolution smaller than the set, the output is switched off. Characteristics Precision setting with a multi-turn trimmer.
Backup power protection.
Output co-configuration: PNP transistor, open collector.
Short-circuit protection.
Overvoltage protection at inductive load.
Two-color light indication of the operating state: red – on output, green – passing object

TECHNICAL PARAMETERS:

Range of regulation

ISxxPxxL1: 6 … 120 min ¹

ISxxPxxL2: 100 … 2000 min

Distance of action Sn
IS18P2E1Lx: 5mm on request
IS30P2E1Lx: 10mm
IS40P2E1Lx: 15mm
IS52P22Lx: 15mm
Recommended installation distance: Sa = <80% of Sn
Supply voltage: DC 12 … 30 V
Consumed current: up to 10 mA
Switching current: up to 250 mA
Residual voltage: up to 1.2 V
Degree of protection: IP65
Operating temperature: 10 ° C … + 70 ° C
ISxxP2E1Lx connection: 2m cable 3×0,25mm2, polyurethane
IS52P22Lx: terminal box

Индуктивен датчик за контрол на обороти
Индуктивен датчик за контрол на обороти

CONNECTION SCHEME:

Caution !: Two-wire AC sensors do not have short-circuit protection in the circuit. It is not allowed to connect the sensor without load in its chain!

Индуктивен датчик за контрол на обороти

Mounting to exclude effort on the housing or cable. The sensors should be fastened using the nuts supplied.
Attention! In the sensor head area, the allowable torque for tightening the nuts is reduced by half!

Allowable torque for metal housing: M30x1.5, M40x1.5 – 40Nm. Permissible tightening torque for plastic housing – 1.5Nm.